top of page
Anchor 1
Anchor 2
Search

HOW TO FIX ERROR CODE 45

ree



Error Code 45

EC45 or Error Code 45


An Error Code 45 is specific to NRCP and CB models. It indicates an internal water leak. There is a water leak sensor at the bottom of the unit behind the circuit board. If enough water accumulates in the well and trips the sensor an Error Code 45 will appear.


The first step is to dry out the well and sensor and look for signs of a water leak. If a part is found to be the source it will need to be replaced. If there is no obvious signs of the water source it could be condensation that formed due to temperature differences between parts of the unit and the environment. If the EC45 continues to show up that’s a good indication that there is an internal leak somewhere that needs to be addressed.

 
 
 

Recent Posts

See All
Rinnai error code 79

Rinnai error code 79 indicates a water leak The leak can be caused by condensation, a faulty heat exchanger, or other internal leaks. ...

 
 
 
How to Fix Navien Error Code E004

When we have a Navien error code E004. There might be different issues with it. - blockage in the venting system.If you have a blockage,...

 
 
 
How to Fix Noritz Error Code 16

EC16 or Error Code 16 The 16 error code occurs when the outlet water temperature spikes to an abnormally high value. The heater will...

 
 
 